Sentinel server activation error 201 is posted during re-activation of network license
Problem:
You receive an error 201 when attempting to re-activate a Sentinel license server for JAWS, ZoomText or Fusion products.
Applies to:
JAWS
Zoomtext
Fusion
Cause/explanation:
The activation system needs a new locking code to be generated for successful activation of a network license.
Resolution:
This problem can occur if the Sentinel server has dropped a license and you attempt to re-activate with the same locking code. Causing a new locking code to be generated will allow successful activation using the steps below.
- Open the following path to location of hidden/system files:
“c:\program files\Freedom Scientific\Activator”
Within this folder locate and delete the following files:
FSShell32.dll
FSShellext.dll
HWD.INI
Note: If you do not see the above files, please make sure you have hidden/system/protected operating files showing in folder options.
- After deleting the files above open “services.msc” and then stop and restart the “SentinelLM” service. This will force generation of a new locking code which you can use to re-activate the server again.
Related Articles
FS Auth - Sentinel Server Manual activation
Problem A Freedom Scientific Network License product customer needs to activate their Sentinel License Server manually. Application Use the steps below if the connection is known to be firewalled/managed or when online activation generates an error ...
FS Auth – Sentinel server activation “Freedom Scientific Connection Error”
Problem When attempting to activate a Network License the error message “Freedom Scientific Connection Error” stating “There is an error with your internet connection” is displayed. Applies to JAWS ZoomText Fusion Resolution The error stated is ...
FS Auth - Activation “Error validating license code” (Network License)
Problem When attempting to activate a Network License for Freedom Scientific product you receive an the message "error validating license code". Resolution Step 1 - Check license type Please click Get detailed product authorisation information, then ...
FS Auth - Activate Freedom Scientific Network product license
Problem A customer needs to activate a network license for a Freedom Scientific BLV product JAWS/ZoomrText/Fusion. Applies to JAWS ZoomText Fusion Note Network license operation requires use of the Sentinel software to distribute the license to ...
FS Auth - Moving Sentinel Server to new hardware (Network License)
Problem An existing Freedom Scientific Sentinel License Server has reached the end of its life and needs replace with new hardware. Applies to JAWS (Network License) ZoomText (Network License) Fusion (Network License) Resolution Please see below ...